*These products are available on a made-to-order basis.
Details are available upon request.
| % of Ampere Rating (A) |
Operating Time |
| Min |
Max |
| 100% |
4 hrs. |
- |
| 135% |
120 sec. |
1800 sec. |
| 200% |
1 sec. |
15 sec. |
| 350% |
0.3 sec. |
5 sec. |
| 600% |
0.1 sec. |
1 sec. |
*Fuses characteristics may vary according to the conditions under which they are used.
Rated Voltage: DC58V or less
Current Cycling(ambient temperature=24°C):
Fuses satisfy performance requirements after 50% of the rated current is applied for 1,000,000 cycles. Each cycle consists of an interrupted current with the pattern of 5 minutes ON and 10 minutes OFF.
Percentage of change in fuse current carrying capacity with change in ambient temperature:
-0.14%/1°C
Standard:ISO 8820/JASO D612
| Part Number |
Ampere Rating (A) |
Housing Color |
| 3102 |
80 |
Red |
| 3112 |
100 |
Yellow |
| 3122 |
125 |
Green |
| 3132 |
150 |
Orange |
| 3142 |
175 |
White |
| 3152 |
200 |
Blue |
| 3162 |
225 |
Light Brown |
| 3172 |
250 |
Pink |
| 3182 |
300 |
Gray |