| % of Ampere Rating (A) |
Operating Time |
| Min |
Max |
| 110% |
100 hrs. |
- |
| 200% |
5 sec. |
100 sec. |
| 350% |
0.2 sec. |
7 sec. |
| 600% |
0.04 sec. |
1 sec. |
*Fuses characteristics may vary according to the conditions under which they are used.
Rated Voltage: DC58V or less
Current Cycling(ambient temperature=24°C):
Fuses satisfy performance requirements after 50% of the rated current is applied for 1,000,000 cycles. Each cycle consists of an interrupted current with the pattern of 5 minutes ON and 10 minutes OFF.
Percentage of change in fuse current carrying capacity with change in ambient temperature:
-0.14%/1°C
Standard:ISO 8820/JASO D612
| Part Number |
Ampere Rating (A) |
Housing Color |
| 3233 |
30 |
Pink |
| 3243 |
40 |
Green |
| 3253 |
50 |
Red |
| 3263 |
60 |
Yellow |
| 3273 |
70 |
Brown |
| 3283 |
80 |
Black |
| 3303 |
100 |
Blue |
| 3323 |
120 |
White |
| 3343 |
140 |
Maroon |